GB-Swindon: UKRI-2291 Radiation Monitors for Gamma Detection Outside Concrete Test Facility Shielding
Estimated value
£72k
Awarded value
£72k
Suppliers
1
Lots
1
Published
02 Nov 2022
Description
This tender requires the design, manufacture, quality control testing and calibration of an initial eight (8), fixed ionising radiation monitors and applicable control software with the option of purchasing an additional four (4) in the subsequent three years. The intended use for these monitors is in fixed occupied locations outside the primary shielding. In these locations, radiation is heavily attenuated by the accelerator components and shielding structures. The shielding has been designed such that dose rates external to the shield walls of the accelerator should be below 1 µSv/h, however, unexpected beam losses can occur which could lead to unplanned, elevated dose rates above the design criteria outside the enclosure. The purpose of these monitors is to detect dose rates at systematically selected locations around the accelerator and either warn those in the vicinity or terminate power to the accelerator depending on the magnitude of the detected dose rate.
Scope
- Reference
- BIP732530400
- Total value
- £72,047.04 excluding VAT
- Commercial tool
- Standalone contract
- Contract dates
- 15 Sept 2022 to 30 Mar 2023
- CPV classifications
- 38341600
Submission & procedure
- Submission deadline
- 14 Sept 2022, 11:00 pm
Award details
Awarded supplier(s), contract period and value as published in the award notice.
Awarded value
£72k
Award date
14 Sept 2022
Contract start
15 Sept 2022
Contract end
30 Mar 2023