PS.
PublicSupply
account_balanceBuyersbusinessSuppliersdescriptionNotices

Procurement notices · Find a Tender + Contracts Finder

Notices

Every UK public-sector procurement notice in one board — open opportunities, closed tenders, awards, and pre-market signals. Filter by deadline, value or CPV, and save your search as an alert.

FiltersReset all
Quick views
  • All open noticesLive opportunities
  • Closing today / tomorrow
  • Closing this week
  • Newly published (24h)
  • High value (£10m+)
  • Awards · last 7 daysMarket signal
  • Pre-market signalsFuture procurements
  • Recently closedAwaiting outcome
  • All noticesEvery PA23 type
Type
  • All
  • Services
  • Supplies
  • Works
Value
  • Any
  • £100k+
  • £1m+
  • £10m+
  • £100m+
Published
  • Any
  • Last 24 hours
  • Last 7 days
  • Last 30 days
Outcome
  • All
  • Awaiting award
  • Cancelled
  • Withdrawn
  • Unsuccessful
Closed since
  • Any
  • Closed ≤ 30 days
  • Closed ≤ 90 days
  • Closed ≤ 12 months
Category
  • All categories
  • IT services
  • Software packages
  • Business services
  • Health & social
  • Construction work
  • Medical equipment
  • Architecture & engineering
  • Repair & maintenance
  • Financial services
  • Education & training
ActiveView: Closed×Clear all
verified_userData sourced from Contracts Finder, Find a Tender, and Companies House.
Contracts Finder ↗Find a Tender ↗Procurement Act 2023 ↗
Closing 24h
4
Open notices
Closing this week
5
Don’t miss
Open · all
70,824
Live opportunities
Posted · 24h
208
New notices
Posted · 30d
7,222
All notice types
Awarded · 7d
936
Market signal

Notice peek

×
NP
ClosedCF · 309f9a7a1228

RFQ - BioCentrifuge and Rotors 129563

National Physical Laboratory
Status
Closed
Estimated
—
Published
20 Jan 2025

Key facts

Notice ID
cf-eefb77a0-5f57-4ac8-9e60-309f9a7a1228
CPV code
38000000 · Laboratory equipment
Source
Contracts Finder

Timeline

  1. Published
    20 Jan 2025

Description

The National Physical Laboratory [NPL] requirement is for a floor-standing centrifuge with a set of compatible rotors to be used for biological applications. The purpose is to perform key steps in cell culturing, protein production and DNA purification. These include, for example, collecting bacterial and mammalian cells from large-scale cell cultures, separation of cell debris from the soluble fraction of cell lysate, pelleting of DNA precipitate and removal of excess liquids in centrifugal and binding columns for protein and DNA purification. The centrifuge needs to be a floor-standing, bio-safe, temperature controlled, and compatible with all selected rotors. The centrifuge must be able to accommodate a range of volumes, up to 6 litres, and run with a variety speeds, up to at least 75,000 relative centrifugal force, when used with suitable rotors. The set of rotors must cover the required speeds, volumes, and bottle/tube requirements. The centrifuge must allow controlled centrifugation of biological solution and mixtures with following specs: 1) Temperature control of range from at least +0°C to +37°C during run, and continuous cooling feature after a run. 2) The centrifuge must be capable of variable centrifugation times. 3) The centrifuge must be equipped with an operating panel with start and stop buttons, options for centrifuge programming and ability to switch display speeds between revolutions per minute (RPM) and relative centrifugal force (RFC). 4) Equipped with an imbalance detector and automated stop of a run if imbalance is detected. 5) Rotor set-up requirement and respective in build max speed controls. 6) Compatibility with at least 4 different rotors and their possible adapters with the specifications set out below: 7) For pelleting large-scale cell cultures: A fixed-angle (15-25°), bio-certified rotor and with a locking with capacity for at least 6x1000 mL / 95x191 mm reusable centrifugal bottles and at least 15,000 RFC. 8) For pelleting cell debris in solution: A fixed-angle (30-40°), bio-certified, rotor and locking lid with capacity for at least 8x50 mL / 29x104 mm centrifugal tubes and minimum of 75,000 RFC. 9) For pelleting precipitated DNA: A fixed-angle (30-40°), bio-certified, lightweight, rotor with a locking lid with capacity for minimum of 8x50mL standard conical tubes and at least 20,000 RFC. 10) For multipurpose use: Swinging bucket, bio-certified, rotor with anodized aluminium buckets designed for use with adapters to accommodate a wide range of tubes, plates and bottles, and at least 5,000 RFC with compatible adaptors: a. for at least 6 x 15 mL standard conical tubes per bucket b. for at least 6 x 50 mL standard conical tubes per bucket 11) The centrifuge and the set of rotors must have a lead time maximum of 6 weeks from when the order is placed. The equipment must be delivered and installed to the lab. 12) The obsolete centrifuge and its rotors must be disposed of by the new equipment supplier.

You might also see

  • All National Physical Laboratory notices →
  • All Laboratory equipment notices →
Open full notice ↗View in this tab
165,209 noticesclosed · sorted by publication date
Page 402 of 8261
Time to close
Value
Type
Buyer
Notice
CLOSED
24 Feb
£6.0m
Estimated
Closed
CF
RK
Red Kite Learning Trust
Moorlands Learning Trust Cleaning Services Framework
Sewage & refuse· Published 17 Jan
CLOSED
10 Mar
—
Estimated
Closed
CF
CA
Competition and Markets Authority
Technical Engineering Advice to CMA for any PR24 Water Re-Determination References
Architecture & engineering· Published 17 Jan
CLOSED
07 Mar
—
Estimated
Closed
CF
CS
Castle School
Castle School Catering Tender
Hotel & restaurant· Published 17 Jan
CLOSED
30 Jan
£125k
Estimated
Closed
CF
GM
General Medical Council (GMC)
Data Analysis Services
IT services· Published 17 Jan
CLOSED
20 Feb
£6.0m
Estimated
Closed
CF
SL
South Lakes Housing
Yewbarrow Lodge Redevelopment
Construction work· Published 17 Jan
CLOSED
04 Mar
—
Estimated
Closed
CF
HC
Hereward College
Hereward College Cleaning Tender
Sewage & refuse· Published 17 Jan
CLOSED
14 Feb
—
Estimated
Closed
CF
SH
Southern Housing
Development Norwood Road & Thurlow Park Road
Construction work· Published 17 Jan
CLOSED
17 Jan
—
Estimated
Closed
FTS · Services
CP
Cornwall Partnership NHS Foundation Trust
NHS2265 - IESO Digital Health 24-25
Health & social· Published 17 Jan
CLOSED
31 Jan
—
Estimated
Closed
CF
SC
SKANSKA CONSTRUCTION UK LIMITED
Series 1800: Structural Steel Bridges - A46 Newark Bypass Scheme
Construction materials· Published 17 Jan
CLOSED
07 Feb
—
Estimated
Closed
CF
UU
Ukaea United Kingdom Atomic Energy Authority
High specification oscilloscope
Laboratory equipment· Published 17 Jan
CLOSED
29 Jan
£20k
Estimated
Closed
CF
GA
Guy's and St Thomas' NHS Foundation Trust
Equipment Maintenance for Ionising Radiology Devices Reference: ST24-P386
Repair & maintenance· Published 17 Jan
CLOSED
31 Jan
—
Estimated
Closed
CF
SC
SKANSKA CONSTRUCTION UK LIMITED
Series 1700: Formwork Reinforcement Concrete (FRC) - A46 Newark Bypass Scheme
Construction work· Published 17 Jan
CLOSED
31 Jan
—
Estimated
Closed
CF
SC
SKANSKA CONSTRUCTION UK LIMITED
Vibro Stone Columns - A46 Newark Bypass Scheme
Construction materials· Published 17 Jan
CLOSED
31 Jan
—
Estimated
Closed
CF
CO
City of York Council
Provision of E-cigarettes
Health & social· Published 17 Jan
CLOSED
20 Feb
—
Estimated
Closed
CF
UR
UK Research & Innovation
UKRI-3727 Framework Agreement for the provision of The British Antarctic Survey (BAS) Food supplies
Food & beverages· Published 17 Jan
CLOSED
31 Jan
—
Estimated
Closed
CF
SC
SKANSKA CONSTRUCTION UK LIMITED
Sheet Piling - A46 Newark Bypass Scheme
Construction materials· Published 17 Jan
CLOSED
17 Apr
—
Estimated
Closed
CF
SM
Solihull MBC
Older People's Service Market Engagement
Health & social· Published 17 Jan
CLOSED
31 Jan
—
Estimated
Closed
CF
SC
SKANSKA CONSTRUCTION UK LIMITED
Series 1400: Electrical Works for Highways - A46 Newark Bypass Scheme
Construction work· Published 17 Jan
CLOSED
14 Feb
£98k
Estimated
Closed
CF
NB
NHS Blood & Transplant (NHSBT)
Net Zero Strategy Consultancy
Sewage & refuse· Published 17 Jan
CLOSED
29 Jan
£16k
Estimated
Closed
CF
GA
Guy's and St Thomas' NHS Foundation Trust
Equipment Maintenance for Non-Medical, Ancillary Equipment Reference: ST24-P437
Repair & maintenance· Published 17 Jan
Page 402 of 8261
PreviousNext