Provision of Passive Fire Protection
Estimated value
£3.0m
Awarded value
£3.0m
Suppliers
1
Lots
1
Published
16 May 2023
Description
The Contractor will be requested to provide the Employer with Passive Fire Safety works / services including but not limited to the following areas: • Compartmentalise a building through use of fire-resistance rated walls and floors, keeping the fire from spreading quickly and providing time to escape for people in the building. • Fire Doors help compartmentalize a building, while giving its occupants means of escape. • Fire Walls and Floors to separate the building into compartments to stop the spread of fire/smoke from room to room. • Fire Compartmentalisation including fire stopping replacement, supply, and installation of the above. • Remedial works ordered from Fire Risk Assessment report recommendations. The Employer requires the use of third-party certified products which have been independently certified by a UKAS accredited organisation. This provides the following required layers of protection. • A manufacturers declaration of performance. • An original test report. • An effective quality management system in the factory to ensure quality of manufacture. • A regular and independent third-party factory audit. • Product support identification. • Random audit and testing in a furnace • Detailed parameters of usage. • Control of cascaded evidence. • Standardised installation and maintenance information. • Full traceability via permanent labelling or markings. The Employer requires third party accredited and competent installers to ensure that the tested and approved materials are competently installed in accordance with manufacturers test evidence and documentation. The third-party certified Contractors will be required to label and verify the installations specification and prove conformance. Regarding fire door installations the Contractor is required to be a member of a relevant fire door installation certification scheme such as FIRAS/BM TRADA. (Other schemes are available). New fire door installations require certification to prove manufacturers and installation conformance. It i
Scope
- Reference
- 20230516141003-72814
- Total value
- £3,000,000 excluding VAT
- Commercial tool
- Standalone contract
- Contract dates
- 14 May 2023 to 29 Apr 2026
- CPV classifications
- 44000000 44221220 45343100
- Particular suitability
- Small and medium-sized enterprises (SME)
Submission & procedure
- Submission deadline
- 02 Mar 2023, 12:00 pm
Award details
Awarded supplier(s), contract period and value as published in the award notice.
Awarded value
£3.0m
Award date
09 May 2023
Contract start
14 May 2023
Contract end
29 Apr 2026
Awarded suppliers· 1 supplier
Awarded 09 May 2023 · Contract period 14 May 2023 — 29 Apr 2026
Other contracts from Ukaea United Kingdom Atomic Energy Authority
Full notice and award history for this contracting authority is on the buyer profile.
Other contracts awarded to Gunfire Limited· 8
Cross-buyer view of this supplier's public-sector wins.
| Title | Type | Value | Published |
|---|---|---|---|
| Housing Solutions - Supply and installation of Fire Doors | contract | — | 19 Feb 2026 |
| Housing Solutions - Supply and installation of Fire Doors | contract | — | 18 Dec 2025 |
| UWQ298 Fire Door Remedial Works - AWARD | contract | £40k | 14 May 2025 |
| Building and Fire Safety Framework | contract | £31.5m | 11 May 2023 |
| Building and Fire Safety Framework | contract | — | 11 May 2023 |
| Replacement Multi- Leaf Fire Exit Doors to Stevenage Arts & Leisure Centre | contract | £36k | 27 Apr 2023 |
| Project 1761 - Fire Door Surveys and Fire Compartmentation Surveys - Various Schools | call off | £12k | 31 Jan 2023 |
| Fire-stopping works at Piper Close, Caledonian Rd and Cottage Rd | contract | £308k | 25 Sept 2018 |